Overcurrent and feeder protection SIPROTEC 7SJ85

Overcurrent and feeder protection SIPROTEC 7SJ85

Product Overview

The SIPROTEC 7SJ85 overcurrent protection has been designed specifically for the protection of feeders, lines and capacitor banks.

Features :

Main function:

  • Feeder and overcurrent protection for all voltage levels

Inputs and outputs:

5 predefined standard variants with

  • 4 current transformers,
  • 4 voltage transformers,
  • 11 to 59 binary inputs,
  • 9 to 33 binary outputs

Hardware flexibility:

  • Flexibly adjustable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5 system; 1/6 expansion modules can be added, available with large or small display, or without display

Housing width:

  • 1/3 × 19 inches to 2/1 × 19 inches

As standard:

Functions :

DIGSI 5 permits all functions to be configured and combined as required.

  • Directional and non-directional overcurrent protection with additional functions
  • Protection of up to 9 feeders with up to 40 analog inputs
  • Optimized tripping times due to directional comparison and protection data communication
  • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos φ, sin φ, dir. detection of intermittent ground faults, harmonic detection and admittance measurement
  • Detection of intermittent ground faults with automatic blocking of static measuring functions, to avoid message and fault record flooding
  • Ground fault detection using the pulse detection method
  • Fault locator plus for accurate fault location with inhomogenous line sections and targeted automatic overhead-line section reclosing (AREC)
  • Arc protection
  • Overvoltage and undervoltage protection
  • Power protection, configurable as active or reactive power protection
  • Frequency protection and frequency change protection for load shedding applications
  • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
  • Protection functions for capacitor banks, such as overcurrent, overload, current unbalance, peak overvoltage, or differential protection
  • Directional reactive power undervoltage protection (QU protection)
  • Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as peak overvoltage protection for capacitors) and operational measured values
  • PQ-Basic: voltage unbalance; voltage changes: overvoltage, dip, interruption; TDD, THD and Harmonics
  • Point-on-wave switching
  • Control, synchrocheck and switchgear interlocking protection
  • Circuit-Breaker Failure Protection
  • Circuit breaker reignition monitoring
  • Graphical logic editor to create powerful automation functions in the device
  • Single-line representation in small or large display
  • Fixed integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
  • Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 61850-9-2 Client, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO, PROFINET IO S2 redundancy)
  • Virtual network sharing (IEEE 802.1Q – VLAN)
  • Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
  • Reliable data transmission via PRP and HSR redundancy protocols
  • Extensive cybersecurity functionality, such as role-based access control (RBAC), protocolling security-related events,  signed firmware or authenticated network access IEEE 802.1X
  • Simple, quick and secure access to the device via a standard Web browser to display all information and diagnostic data, as well as vector diagrams, single-line and device display pages
  • Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
  • Time synchronization using IEEE 1588
  • Control of Power Transformers
  • Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
  • Auxiliary functions for simple tests and commissioning

More Information